The Largest IN-STOCK FLOW METER Warehouse + Ships Same Day!

Authorized Distributor of FLOMEC & GPI Flow Meters

OM025P001-822

1" NPT Female PPS

Pulse Out OM Series - OVAL GEAR

$702.00
Lead Time: 2-3 Weeks
Main Specifications
Connection Size: 1"
Connection Type: NPT Female
Flow Range: 2.6 - 40 GPM (10-150 LPM)
Pressure Rating: 70 PSI (5 Bar)
Meter Body Size: 1"
Local/Remote Display: None
Display Type: None
Flow Meter Type: OM Series - OVAL GEAR
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Product Type: Pulse Out
Benefits & Features: Excellent for applications with fluctuating or multiple viscosities - No field calibrating required; Accuracy: ± 0.5% Of Reading; Up to 1,000 cps Viscosity; No straight pipe requirements; Bi-directional; PPS Rotors are immune to galling (adhesive wear); PPS Rotors produce less noise than metal rotors
Max Pressure Drop (at Max Flow in test conditions): Contact us
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5% @ 3cp
Repeatability (based on test conditions): ± 0.03%
Maximum Viscosity: 1,000 cps
Recommended Strainer Size: 100 Mesh (150 Microns)
Max. Particle Size: .006" / .149 mm
Housing Material: PPS
Bearings: None
Shaft: Carbon Ceramic
Rotor: PPS
Seals: FKM (Viton™)
Typical K-Factor PPG (PPL): Reed: 120 (27), Hall Effect: 405 (107)
Local Module & Output Signal: Open Collector (NPN) Unscaled Pulse
Remote Output: None
Sensor (Pickup): Reed Switch / Hall Effect<br>[Hall Effect Sensor requires dedicated power source]
Applications (always check Chemical Compatibility Guide): Metering clean fluids such as water based liquids, including water based acids, bases or neutral salts and most fuels, fuel oils and lubricating liquids. Resistant to chemical attack from all non-aromatic (containing benzene), non-halogenated (containing halogens such as chlorine, bromine) organic solvents at any concentration. Suited for heated water, sea water, water with <1% chlorine up to 176°F.
Not Suitable For Applications: Dirty liquids, strong oxidizing acids such as nitric acid, hydrofluoric acid and hydrochloric acid, or any strong acids (ph <2) at temperatures above normal ambient. Strong bases at high temperatures. Oxidizing chemicals in high concentrations. Hydrogen Peroxide. Chlorine and Sodium Hypochlorite.
Minimum Straight Pipe Dia.s: None
Desired Straight Pipe Dia.s: None
Application Notes: The meter may be mounted horizontally or vertically but must be mounted, so the rotor shafts are in a horizontal plane (see manual), For viscous liquids, the maximum allowable flow may need to be reduced to ensure the pressure drop across the meter does NOT exceed 15 PSI, Viscosities <3cps, min. flow range is 10% of the maximum flow range, Line must be full (no air) for proper accuracy
Connection to Connection Length (OAL): 4.9" (104mm)
Shipping Weight (Approximate): 6 lbs (2.7 kg)
Approvals Notes: CE Approval is applied when meter is part of a system