The Largest IN-STOCK FLOW METER Warehouse + Ships Same Day!

Authorized Distributor of FLOMEC & GPI Flow Meters

OM025P001-826R7G

1" NPT Female PPS

Rate & Totals OM Series - OVAL GEAR

$1064.00
Lead Time: In Stock April 12
Main Specifications
Connection Size: 1"
Connection Type: NPT Female
Flow Range: 2.6 - 40 GPM (10-150 LPM)
Pressure Rating: 70 PSI (5 Bar)
Operating Temp With Local Computer: 5 to 176°F (-15 to 80°C)
Meter Body Size: 1"
Local/Remote Display: Local
Display Type: Digital LCD (GRN Housing)
Flow Meter Type: OM Series - OVAL GEAR
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Product Type: Rate & Totals
Benefits & Features: Excellent for applications with fluctuating or multiple viscosities - No field calibrating required; Accuracy: ± 0.5% Of Reading; Up to 1,000 cps Viscosity; No straight pipe requirements; Bi-directional; PPS Rotors are immune to galling (adhesive wear); PPS Rotors produce less noise than metal rotors; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Choice of Gallons or Liters; Custom Programmable Display (including UOM); Back-lighted Display when powered externally
Max Pressure Drop (at Max Flow in test conditions): Contact us
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5% @ 3cp
Repeatability (based on test conditions): ± 0.03%
Maximum Viscosity: 1,000 cps
Recommended Strainer Size: 100 Mesh (150 Microns)
Max. Particle Size: .006" / .149 mm
Operating Temp Without Local Computer or With Remote Computer: 5 to 176°F (-15 to 80°C) [Opt'l]
Housing Material: PPS
Bearings: None
Shaft: Carbon Ceramic
Rotor: PPS
Seals: FKM (Viton™)
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Typical K-Factor PPG (PPL): Reed: 120 (27), Hall Effect: 405 (107)
Local Module & Output Signal: None (RT40)
Remote Output: None
Battery Power: (1) 3.6V battery (~3 years)
External Power: Regulated 8-24VDC x 50mA minimum
Totalizing Resets to 0 After Reaching: 99999999
Sensor (Pickup): Reed Switch / Hall Effect<br>[Hall Effect Sensor requires dedicated power source]
Applications (always check Chemical Compatibility Guide): Metering clean fluids such as water based liquids, including water based acids, bases or neutral salts and most fuels, fuel oils and lubricating liquids. Resistant to chemical attack from all non-aromatic (containing benzene), non-halogenated (containing halogens such as chlorine, bromine) organic solvents at any concentration. Suited for heated water, sea water, water with <1% chlorine up to 176°F.
Not Suitable For Applications: Dirty liquids, strong oxidizing acids, strong bases at high temperatures, oxidizing chemicals in high concentrations, Hydrogen Peroxide, Chlorine and Sodium Hypochlorite
Minimum Straight Pipe Dia.s: None
Desired Straight Pipe Dia.s: None
Application Notes: The meter may be mounted horizontally or vertically but must be mounted, so the rotor shafts are in a horizontal plane (see manual), For viscous liquids, the maximum allowable flow may need to be reduced to ensure the pressure drop across the meter does NOT exceed 15 PSI, Viscosities <3cps, min. flow range is 10% of the maximum flow range, Line must be full (no air) for proper accuracy. External Power is required for the backlit display.
Connection to Connection Length (OAL): 4.9" (104mm)
Shipping Weight (Approximate): 8 lbs (3.6 kg)