G2A07N09GMA (3/4" NPT Female) Aluminum

Sub Model No. A07N G2 Series - INDUSTRIAL GRADE METER Turbine Type

$716.00

List: $895.00 icon-stockIn Stock Now!

Main Specifications

  • Housing Material: Aluminum
  • Meter Body Size: 3/4"
  • Connection Size: 3/4"
  • Connection Type: NPT Female
  • Design: Alum. Industrial Grade Turbine Meter (300 PSI)
  • Flow Range: 2 - 20 GPM (7.6 - 75.7 LPM)

Approvals

Features & Benefits

Accurate; Durable; 5-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)

Applications

Fuel, Diesel, Petroleum Based Products

Application Notes

Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds

Flow Specifications

  • Extended Flow Range: 20 - 30 GPM (75.7 - 113.6 LPM)*
  • Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
  • Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
  • Repeatability (based on test conditions): ± 0.1%
  • Pressure Rating: 300 PSI (21 Bar)
  • Operating Temp With Local Computer: 14°F to 140°F (-10°C to 60°C)
  • Operating Temp Without Local Computer or With Remote Computer: -40°F to 250°F (-40°C to 121°C) [Opt'l]
  • Max Pressure Drop (at Max Flow in test conditions): 5.2 PSI
  • Maximum Viscosity: 100 cps**
  • Recommended Strainer Size: 120 Mesh (125 Microns)
  • Max. Particle Size: .005" / .127 mm

Wetted Materials

  • Housing Material: Aluminum
  • Rotor: PVDF
  • Bearings: 96% Alumina Ceramic
  • Shaft: Tungsten Carbide
  • Signal Generator: Not Wetted
  • Retaining Rings: 316SS
  • Seals: n/a

General Information

  • Design: Alum. Industrial Grade Turbine Meter (300 PSI)
  • Std Calibration Reports Included: Yes
  • Local Computer Calibrations: Factory & Field
  • Factory Calibrated For: Water like fluids
  • Warranty Period: 1 Year
  • Approvals Notes: See catalog page for full approval specs
  • Comments: *The accuracy of the extended flow range declines and is not guaranteed
  • Comments: **For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations

Meter Display & Output Signal

  • Display Type: Digital LCD
  • Local/Remote Display: Local
  • Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
  • LCD Digits: 6
  • Totalizing Display Starting Increment: 0.01
  • Totalizing Resets to 0 After Reaching: 99,999,999
  • Remote Output: Optional Remote Display, 4-20mA or Pulse Out (Please contact us)

Options

Please Contact Us For Options

Electronics

  • Typical K-Factor PPG (PPL): 1100 (291)
  • Sensor (Pickup): Magnetic
  • Battery Power: (2) 3V Lithium Battery (5 year)
  • Frequency Range: 37 - 370 Hz

Piping Requirements

  • Desired Straight Pipe Dia.s: 14" Upstream / 7.5" Downstream
  • Minimum Straight Pipe Dia.s: 7.5" Upstream / 3.75" Downstream

Weight & Dimensions

  • Connection to Connection Length (OAL): 4.3" (109 mm)
  • Shipping Weight (Approximate): 1.4 lbs (0.63 kg)