G2H07NQ9GMV
3/4" NPT 316SS Industrial Grade Electronic Meter
                                
                                    3/4" NPT Female 316SS
Rate & Totals G2 Series - INDUSTRIAL GRADE METER - HIGH PRESSURE
Main Specifications
                                    Connection Size: 3/4"
                                    Connection Type: NPT Female
                                    Flow Range: 2 - 20 GPM   (7.6 - 75.7 LPM)
                                    Pressure Rating: 3000 PSI   (207 Bar)
                                    Operating Temp With Local Computer: 
0 to 140°F (-18 to 60°C) for SAFE AREA ONLY (Non-FM Approved)
See Catalog Page link to the left
                            0 to 140°F (-18 to 60°C) for SAFE AREA ONLY (Non-FM Approved)
See Catalog Page link to the left
Meter Body Size: 3/4"
                                    Body Type: High Pressure
                                    Local/Remote Display: Local
                                    Display Type: Digital LCD
                                    Factory Calibrated For: Water like fluids
                                    Flow Meter Type: G2 Series - INDUSTRIAL GRADE METER - HIGH PRESSURE
                                    Std Calibration Reports Included: Yes
                                    Warranty Period: 1 Year
                                    Product Type: Rate & Totals
                                    Benefits & Features: High Pressure Rated (3000 PSI); Excellent Chemical Compatibility; Accurate; Durable; 2-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
                            Max Pressure Drop (at Max Flow in test conditions): 5.2 PSI
                                    Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
                                    Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
                                    Repeatability (based on test conditions): ± 0.1%
                                    Recommended Strainer Size: 120 Mesh  (125 Microns)
                                    Max. Particle Size: .005" / .127 mm
                                    Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F   (-40 to 121°C)  [Opt'l]
                                    Extended Flow Range: 20 - 30 GPM   (75.7 - 113.6 LPM)<br>[Accuracy of the extended flow range declines and is not guaranteed]<br>Overranging damages meter and voids warranty
                                    Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
                            Housing Material: 316SS
                                    Bearings: 96% Alumina Ceramic/Tungsten Carbide
                                    Shaft: Tungsten Carbide
                                    Rotor: PVDF
                                    Signal Generator: Not Wetted
                                    Retaining Rings: 316SS
                            Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
                                    Local Computer Calibrations: Factory & Field
                                    LCD Digits: 6
                                    Totalizing Display Starting Increment: 0.01
                                    Typical K-Factor PPG (PPL): 1100  (291)
                                    Local Module & Output Signal: None
                                    Remote Output: Optional Remote Display, 4-20mA or Pulse Out (Please contact us)
                                    Sensor (Pickup): Magnetic
                                    Battery Power: (2) AAA 1.5V Alkaline Battery (2 year)
                                    Frequency Range: 37 - 370 Hz
                                    Totalizing Resets to 0 After Reaching: 99999999
                            Applications (always check Chemical Compatibility Guide): High Press Water Spray Washers and Hydraulic Systems,  Chemicals,  Fuel Products
                                    Not Suitable For Applications: DI Water;  Oils, especially those heavier than 10W (100cps), Fluctuating viscosities**
                                    Minimum Straight Pipe Dia.s: 7.5" Upstream / 3.75" Downstream
                                    Desired Straight Pipe Dia.s: 14" Upstream / 7.5" Downstream
                                    Application Notes: Unidirectional but Display can be rotated 180°,  Can mount Horizontally or Vertically,  Can use for Gravity Feeds,  Line should be kept full (no air) for proper accuracy
                                    Piping Notes: If cavitation affects accuracy, try a flow control valve downstream of meter
                            Connection to Connection Length (OAL): 4.3"  (109 mm)
                                    Shipping Weight (Approximate): 2.4 lbs  (1.1 kg)
                             
                                     
                                     
                                                                    Approvals Notes: CE Approvals Only; See catalog page for full approval specs
                             
    