GSCPS-200-RT14
2" Tri-Clamp 316SS
Rate & Totals, 4-20mA & Pulse Output GSCPS Series - PRECISON METER - 3-A APPROVED BODY
                                                
                                            
                                                    $4636.00
                                            
                                        
                                    Main Specifications
                                    Connection Size: 2"
                                    Connection Type: Tri-Clamp
                                    Flow Range: 33 - 330 GPM
                                    Pressure Rating: Limited by fitting size, clamp and temperature
                                    Operating Temp With Local Computer: -22°F to 176°F   (-30°C to 80°C)
[SIP (Up to 1 hour) 285°F (140°C). Remove display, pickup, gaskets & clamps not rated to 285°F]
                            [SIP (Up to 1 hour) 285°F (140°C). Remove display, pickup, gaskets & clamps not rated to 285°F]
Meter Body Size: 2"
                                    Body Type: 3-A Approved
                                    Factory Calibrated For: Water like fluids
                                    Flow Meter Type: GSCPS Series - PRECISON METER - 3-A APPROVED BODY
                                    Std Calibration Reports Included: Yes
                                    Warranty Period: 1 Year
                                    Local/Remote Display: Local
                                    Display Type: Digital LCD
                                    Product Type: Rate & Totals, 4-20mA & Pulse Output
                                    Benefits & Features: The body meets strict 3-A Sanitary Standards using the new "Third Party Verification" (TPV) program; Internals are machined or polished to meet 3-A self-draining and cleaning requirements (Ra32); CIP, SIP, COP;  High Accuracy: ± 0.5% (Linearity); Field Serviceable; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
                            Max Pressure Drop (at Max Flow in test conditions): 14 PSI
                                    Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5%
                                    Repeatability (based on test conditions): ± 0.1%
                                    Recommended Strainer Size: 14 Mesh  (1410 Microns)
                                    Max. Particle Size: .056" / 1.410 mm
                                    Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
                                    Operating Temp Without Local Computer or With Remote Computer: -100 to 225°F  (-74 to 107°C) [Opt'l]
                            Housing Material: 316SS
                                    Bearings: PEEK
                                    Shaft: 316SS
                                    Thrust Bearings: PEEK
                                    Rotor: CD4MCu Stainless Steel (Nickel Plated)
                                    Rotor Supports: 316SS
                                    Signal Generator: Not Wetted
                                    Retaining Rings: 302SS/316SS
                            Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
                                    Local Computer Calibrations: Factory & Field
                                    LCD Digits: 6
                                    Totalizing Display Starting Increment: 0.01
                                    Sensor (Pickup): Magnetic
                                    Battery Power: 3.6V Battery (~2 year life)
                                    External Power: Regulated 8-24VDC (opt'l)
                                    Frequency Range: 100 - 1000 Hz
                                    Totalizing Resets to 0 After Reaching: 99999999
                                    Typical K-Factor PPG (PPL): 183
                            Applications (always check Chemical Compatibility Guide): 3A Approved Food & Beverage,  Beer,  Wine,  Dairy
                                    Piping Notes: If pump, valve, etc. is upstream, need min. 40" Upstream
                                    Minimum Straight Pipe Dia.s: 20" Upstream / 10" Downstream
                                    Application Notes: See page 5 in the manual for 3-A Recommended Practices,  Unidirectional,  Line must be full (no air) for proper accuracy
                            Connection to Connection Length (OAL): 6.063"  (154.0 mm)
                                    Shipping Weight (Approximate): 12 lbs  (5.4 kg)
                             
                                     
                                     
                                                                    Approvals Notes: Only the turbine body is 3-A Approved; See catalog page for full approval specs
                             
    