OM015A001-242
1/2" 150 lb ANSI Flange Aluminum
Pulse Out OM Series - OVAL GEAR
Main Specifications
                                    Connection Size: 1/2"
                                    Connection Type: 150 lb ANSI Flange
                                    Flow Range: 0.26 - 10.6 GPM  (1-40 LPM)
                                    Pressure Rating: 170 PSI  (11 Bar)
                            Meter Body Size: 1/2"
                                    Local/Remote Display: None
                                    Display Type: None
                                    Flow Meter Type: OM Series - OVAL GEAR
                                    Std Calibration Reports Included: Yes
                                    Warranty Period: 1 Year
                                    Product Type: Pulse Out
                                    Benefits & Features: Excellent for applications with fluctuating or multiple viscosities - No field calibrating required; Accuracy: ± 0.5% Of Reading; Up to 1,000 cps Viscosity; No straight pipe requirements; Bi-directional; PPS Rotors are immune to galling (adhesive wear); PPS Rotors produce less noise than metal rotors
                            Max Pressure Drop (at Max Flow in test conditions): Contact us
                                    Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5% @ 3cp
                                    Repeatability (based on test conditions): ± 0.03%
                                    Maximum Viscosity: 1,000 cps
                                    Recommended Strainer Size: 100 Mesh  (150 Microns)
                                    Max. Particle Size: .006" / .149 mm
                                    Operating Temp Without Local Computer or With Remote Computer: 5 to 250°F  (-15 to 120°C)
                            Housing Material: Aluminum
                                    Bearings: None
                                    Shaft: Stainless Steel
                                    Rotor: PPS
                                    Seals: FKM (Viton™)
                            Typical K-Factor PPG (PPL): Reed: 318 (84), Hall Effect: 636 (138)
                                    Local Module & Output Signal: Open Collector (NPN) Unscaled Pulse
                                    Remote Output: None
                                    Sensor (Pickup): Reed Switch / Hall Effect<br>[Hall Effect Sensor requires dedicated power source]
                            Applications (always check Chemical Compatibility Guide): Metering clean fluids such as Oils,  Grease,  Fuels,  Fuel Oils,  Lubricating Liquids
                                    Not Suitable For Applications: Water, dirty liquids
                                    Minimum Straight Pipe Dia.s: None
                                    Desired Straight Pipe Dia.s: None
                                    Application Notes: The meter may be mounted horizontally or vertically but must be mounted, so the rotor shafts are in a horizontal plane (see manual),  For viscous liquids, the maximum allowable flow may need to be reduced to ensure the pressure drop across the meter does NOT exceed 15 PSI,  Viscosities <3cps, min. flow range is 10% of the maximum flow range,  Line must be full (no air) for proper accuracy
                            Connection to Connection Length (OAL): 7.4"  (189mm)
                                    Shipping Weight (Approximate): 8 lbs  (3.6 kg)
                             
                                                                    Approvals Notes: CE Approval is applied when meter is part of a system
                             
    