QSE10NPTB9XXXA

1" MNPT Pulse Out Magmeter

1" NPT Male Noryl®

Pulse Out QSE Series - MAGMETER

$1226.00
Lead Time: 2-3 Weeks
Main Specifications
Connection Size: 1"
Connection Type: NPT Male
Pressure Rating: 150 PSI @ 73°F
Flow Range: 0.67 - 40 GPM (2.52 - 151 LPM)
Meter Body Size: 1"
Local/Remote Display: Local
Display Type: None
Flow Meter Type: QSE Series - MAGMETER
Benefits & Features: Non-Intrusive, No moving parts to wear out, Low maintenance and repair costs, High Accuracy with quick response time, Can measure with up to 20% solids, Tolerates high flows without damage, Very low pressure drop, Wide turn-down ratio, NIST Reports standard at N/C
Warranty Period: 1 Year
Product Type: Pulse Out
Std Calibration Reports Included: Yes - NIST<br>[NIST Certs come with each meter at no extra charge. Please inquire for certificate's date of our stocked meters.]
Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.5%
Accuracy (% of Reading) Factory Calibrated Body Only: ± 0.5% *
Max. Particle Size: 20% Solids Maximum
Operating Temp Without Local Computer or With Remote Computer: 32° to 180°F (0° to 82°C)
Max Pressure Drop (at Max Flow in test conditions): Negligible
Housing Material: Noryl®
Seals: NBR (Non-Wetted)
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
Typical K-Factor PPG (PPL): 1089
Remote Output: Optional Remote Display, 4-20mA or Pulse Out (Please contact us)
Sensor (Pickup): Electrodes
Battery Power: Requires External Power
External Power: 12-36 VDC
Frequency Range: 10 Hz Minimum - 1,000 Hz Maximum
Applications (always check Chemical Compatibility Guide): Waste Water, Irrigation Systems (Agricultural, Turf and Micro), HVAC, EMS (Energy Management Systems), BAS (Building Automation Systems), Process (blow down, make up, boiler feed, etc.), Chilled Water, Heating/Cooling Loops, Residential/Tenant water usage with low flow detection down to 0.15 GPM
Not Suitable For Applications: DI Water, Petroleum Products, In hazardous locations, Medias with bubbles, Fluids with conductivity of < 20µS/cm (see manual, page 2)
Piping Notes: Optimal horizontal position: top of meter at 1 or 2 o'clock
Minimum Straight Pipe Dia.s: None
Desired Straight Pipe Dia.s: As much as possible
Application Notes: Unidirectional. For horizontal or vertical flows. Do not allow liquids to dry or freeze inside of the meter. NOTE: Requires grounding. See Earth Ground Instructions manual.
Connection to Connection Length (OAL): 11.00" (279.4mm)
Shipping Weight (Approximate): 4 lbs (1.8 kg)
Approvals Notes: IP67, CE, CSA